| GENERAL SPECIFICATIONS |
| Adaper Supply Voltage: |
100-240 VAC, 47-63 Hz, 1.35A |
| Adapter Output: |
15V - 3A Max. |
| Adapter Dimensions: |
143mm (L) x 73mm (W) x 40mm (H) |
| Dimensions: |
250mm (L) x 185mm (W) x 82 mm (H) |
| Operating Environment: |
Temperature: 10°C (50°F) to 40°C (104°F) Relative Humidity: 30% - 85% |
| Storage Environment: |
Temperature: -20°C (-4°F) to 55°C (131°F) Relative Humidity: 20% - 90% |
| Maximum Treatment Time: |
60 minutes - electrical stimulation |
| Classification of protection against shock |
Class II medical device |
| Classification of applied part |
Type BF |
|
| 2-Pole Interferential Mode |
| Waveform Type: |
Bi-phasic square |
| Mode Selection: |
CC (Constant Current) or
CV (Constant Voltage) |
| Carrier Frequency (C.F.): |
2.5kHz |
| Sweep Low Beat Frequency:(Beat H.) |
(Beat L.) - 150 Hz |
| Sweep High Bet Frequency:(Beat L.) |
1-(Beat H.) Hz |
| Output Intensity: |
0-50mA (CC, at 1k ohm load)
0-50V (CV, at 1k ohm load) |
| Treatment Time: |
1-60 minutes |
| Cycle Time (Cycle): |
Continuous, 5/5, 4/12, 10/10, 10/20, 10/30, 10/50 |
| Ramp Time (Ramp): |
2 seconds |
| |
|
|
| Ultrasonic Generator Mode |
| Frequency (Freq): |
1MHz ± 10%
3MHz ± 10% |
| Duty Factor (Duty): |
10% - 100% , Stepping 10% |
| Pulse Repetition Rate: |
100 Hz |
| Treatment Time: |
Max. 30 minutes |
| Output Power: |
0.5W - 10.0W, when duty factor ≥ 80% for 5cm²
0.5W - 15.0W, when duty factor ≤ 70% for 5cm²
0.1W - 2.0W, when duty factor ≥ 80% for 1cm²
0.1W - 3.0W, when duty factor ≤ 70% for 1cm² |
| Effective radiating area (Aer) |
1. 0cm² Optional
5. 0cm² |
| Effective Intensity (Max): |
3. 0W/cm |
| Indication Accuracy: |
± 20% (for any level above 10% of maximum) |
|
| TENS and EMS Mode |
| Wave form type: |
Mono- or Bi-phasic square |
| Mode Selection: |
CC (Constant Current) or
CV (Constant Voltage) |
| Frequency: |
1-250 Hz |
| Frequency modulation (F.M.): |
0-249 Hz |
| Burst Rate (Burst): |
0-10Hz (7 pulse) |
| Phase Duration (P.Dur): |
30-400μs |
| Amplitude Modulation (A.M.) |
0%-100% |
| Output Intensity: |
0-100mA (CC, at 1k ohm load)
0-100V (CV, at 1k ohm load) |
| Cycle Time (Cycle): |
Continuous , 4/4, 4/8, 7/7, 5/5, 4/12,10/10,
10/20, 10/30, 10/50 |
| Treatment Time: |
1-60 minutes |
| Ramp Time: |
1 second |
|
| 4-Pole Interferential Mode |
| Waveform Type: |
Bi-phasic square |
| Mode Selection: |
CC (Constant Current) or
CV (Constant Voltage) |
| Vector: |
Auto: 0%-100%
Manual: 0°-90° |
| Carrier Frequency (C.F.): |
4.0kHz |
Sweep Low Beat Frequency:
(Beat H.) |
(Beat L.) - 150 Hz |
Sweep High Bet Frequency:
(Beat L.) |
1-(Beat H.) Hz |
| Output Intensity: |
0-50mA (CC, at 1k ohm load)
0-50V (CV, at 1k ohm load) |
| Treatment Time: |
1-60 minutes |
|
| Russian Mode |
| Waveform Type: |
Bi-phasic square |
| Mode Selection: |
CC (Constant Current) or
CV (Constant Voltage) |
| Carrier Frequency (C.F.): |
2.5kHz |
| Burst Frequency (Freq.) |
20-100 Hz |
| Output Intensity: |
0-50mA (CC, at 1k ohm load)
0-50V (CV, at 1k ohm load) |
| Duty Cycle: |
10%, 20%, 30%, 40%, and 50% |
| Treatment Time: |
1-60 minutes |
| Ramp Time (Ramp): |
1s, 2s, and 5s |
|