The microprocessor controlled Quattro II is a professional four-channel electrotherapy device that provides IF 4-Pole, IF 2-Pole, Russian, EMS and TENS waveform. It’s portable design lets you take it to your patient or keep it at the clinic. It’s easy to use and up and running within minutes. And it’s advanced operating system ensures a complete range of therapy no matter where you use it! You can choose between several different amplitude modulation options. The interferential and premodulated modes offer frequency modulation as well as a static frequency option.
Click here To Download the Specification File |
GENERAL SPECIFICATIONS |
| Adapter Supply Voltage: |
100-240 VAC, 50-60Hz, 0.5A |
| Adapter Output: |
15V — 1A Max. |
| Adapter Dimensions: |
110mm (L) x 185mm (W) x 33mm (H) |
| Dimensions: |
250mm (L) x 185mm (W) x 82 mm (H) |
| Operating Environment: |
Temperature: 10⁰C (50⁰F) to 40⁰C (104⁰F)
Relative Humidity: 30% - 85% |
| Storage Environment: |
Temperature: -20⁰C (-4⁰F) to 55⁰C (131⁰F)
Relative Humidity: 20% - 90% |
| Maximum Treatment Time: |
60 minutes |
|
TENS and EMS Mode |
| Waveform Type: |
Mono- or Bi-phasic square |
| Mode Selection: |
CC (Constant Current) or
CV (Constant Voltage) |
| Frequency: |
1-250 Hz |
| Frequency modulation (F.M.): |
0-249 Hz |
| Burst Rate (Burst): |
0-10Hz (7 pulse) |
| Phase Duration(P.Dur): |
30-400μs |
| Amplitude Modulation (A.M.) |
0%-100% |
| Output Intensity: |
0-100mA (CC, at 1k ohm load)
0-100V (CV, at 1k ohm load) |
| Cycle Time (Cycle): |
Continuous , 4/4, 4/8, 7/7, 5/5, 4/12,10/10, 10/20, 10/30, 10/50 |
| Treatment Time: |
1-60 minutes |
| Ramp Time: |
1 second |
|
4-Pole Interferential Mode |
| Waveform Type: |
Bi-phasic square |
| Mode Selection: |
CC (Constant Current) or
CV (Constant Voltage) |
| Vector: |
Auto: 0%-100%
Manual: 0⁰-90⁰ |
| Carrier Frequency(C.F.): |
4.0kHz |
Sweep Low Beat Frequency:
(Beat H.) |
(Beat L.) - 150 Hz |
Sweep High Bet Frequency:
(Beat L.) |
1-(Beat H.) Hz |
| Output Intensity: |
0-50mA (CC, at 1k ohm load)
0-50V (CV, at 1k ohm load) |
| Treatment Time: |
1-60 minutes |
|
2-Pole Interferential Mode |
| Waveform Type: |
Bi-phasic square |
| Mode Selection: |
CC (Constant Current) or
CV (Constant Voltage) |
| Carrier Frequency(C.F.): |
2.5kHz/td>
|
Sweep Low Beat Frequency:
(Beat H.) |
(Beat L.) - 150 Hz |
Sweep High Bet Frequency:
(Beat L.) |
1-(Beat H.) Hz |
| Output Intensity: |
0-50mA (CC, at 1k ohm load)
0-50V (CV, at 1k ohm load) |
| Treatment Time: |
1-60 minutes |
| Cycle Time (Cycle): |
Continuous, 5/5, 4/12, 10/10, 10/20, 10/30, 10/50 |
| Ramp Time (Ramp): |
2 seconds |
|
Russian Mode |
| Waveform Type: |
Bi-phasic square |
| Mode Selection: |
CC (Constant Current) or
CV (Constant Voltage) |
| Carrier Frequency(C.F.): |
2.5kHz |
| Burst Frequency(Freq.) |
20-100 Hz |
| Output Intensity: |
0-50mA (CC, at 1k ohm load)
0-50V (CV, at 1k ohm load) |
| Duty Cycle: |
10%, 20%, 30%, 40%, and 50% |
| Treatment Time: |
1-60 minutes |
| Ramp Time (Ramp): |